Current pulse based ion-selective electrodes for chronopotentiometric determination of calcium in seawater | |
Liu, Shuwen; Ding, Jiawang; Qin, Wei | |
发表期刊 | ANALYTICA CHIMICA ACTA |
ISSN | 0003-2670 |
2018-11-15 | |
卷号 | 1031页码:67-74 |
关键词 | Chronopotentiometry Ion-selective electrode Calcium Seawater Current pulse |
研究领域 | Chemistry |
DOI | 10.1016/j.aca.2018.06.018 |
产权排序 | [Liu, Shuwen; Ding, Jiawang; Qin, Wei] Chinese Acad Sci, Key Lab Coastal Environm Proc & Ecol Remediat, Shandong Prov Key Lab Coastal Environm Proc, Yantai Inst Coastal Zone Res YIC,YICCAS, Yantai 264003, Shandong, Peoples R China; [Ding, Jiawang; Qin, Wei] Qingdao Natl Lab Marine Sci & Technol, Lab Marine Biol & Biotechnol, Qingdao 266237, Peoples R China; [Liu, Shuwen] Univ Chinese Acad Sci, Beijing 100049, Peoples R China |
作者部门 | 海岸带环境过程实验室 |
英文摘要 | Calcium is closely related to the oceanic biosphere and carbonate system. Potentiometry based on a calcium-selective electrode (Ca-ISE) represents a promising tool for detection of calcium ion activities in seawater. This technique, however, generally is limited by the low sensitivity for the inherent Nernstian response (i.e. ca 30 mV/dec). A current pulse based ion-selective electrode with enhanced sensitivity for chronopotentiometric measurements of calcium in seawater is proposed. The Ca2+-selective membrane containing lipophilic salt ETH 500 instead of traditional ion-exchanger is galvanostatically controlled. An applied constant cathodic current pulse can leads to the extraction of the calcium ions into the membrane to produce a chronopotential response, which shows a stable and reproducible super-Nernstian response in a narrow calcium activity range. The super-Nernstian region of the electrode depends on not only the the magnitude and duration of the applied current pulse but also the interfering ions. Under optimal conditions, the proposed Ca-ISE exhibits a super-Nernstian response between the calcium concentrations of 10(-)(2.5)-10(-)(1.5)M with a slope of ca 80 mV/dec. The current pulse based Ca-ISE has been applied to determination of calcium in seawater with satisfactory results. (C) 2018 Published by Elsevier B.V. |
文章类型 | Article |
资助机构 | National Natural Science Foundation of China [21575158, 21677172] ; Chinese Academy of Sciences [Y728021021] ; National Key Research and Development Program of China [2016YFC1400700] ; CAS Youth Innovation Promotion Association [2014190] ; Taishan Scholar Program of Shandong Province [TS20081159] |
收录类别 | SCI |
语种 | 英语 |
关键词[WOS] | GALVANOSTATIC CONTROL ; MASS-SPECTROMETRY ; ALKALINITY ; MAGNESIUM ; HEPARIN ; RATIOS ; CARBON ; WATER ; SEA ; SPECIATION |
研究领域[WOS] | Chemistry, Analytical |
WOS记录号 | WOS:000441511600007 |
引用统计 | |
文献类型 | 期刊论文 |
条目标识符 | http://ir.yic.ac.cn/handle/133337/24576 |
专题 | 中国科学院海岸带环境过程与生态修复重点实验室_海岸带环境过程实验室 中国科学院海岸带环境过程与生态修复重点实验室 |
作者单位 | 1.Chinese Acad Sci, Key Lab Coastal Environm Proc & Ecol Remediat, Shandong Prov Key Lab Coastal Environm Proc, Yantai Inst Coastal Zone Res YIC,YICCAS, Yantai 264003, Shandong, Peoples R China; 2.Qingdao Natl Lab Marine Sci & Technol, Lab Marine Biol & Biotechnol, Qingdao 266237, Peoples R China; 3.Univ Chinese Acad Sci, Beijing 100049, Peoples R China |
推荐引用方式 GB/T 7714 | Liu, Shuwen,Ding, Jiawang,Qin, Wei. Current pulse based ion-selective electrodes for chronopotentiometric determination of calcium in seawater[J]. ANALYTICA CHIMICA ACTA,2018,1031:67-74. |
APA | Liu, Shuwen,Ding, Jiawang,&Qin, Wei.(2018).Current pulse based ion-selective electrodes for chronopotentiometric determination of calcium in seawater.ANALYTICA CHIMICA ACTA,1031,67-74. |
MLA | Liu, Shuwen,et al."Current pulse based ion-selective electrodes for chronopotentiometric determination of calcium in seawater".ANALYTICA CHIMICA ACTA 1031(2018):67-74. |
条目包含的文件 | 下载所有文件 | |||||
文件名称/大小 | 文献类型 | 版本类型 | 开放类型 | 使用许可 | ||
Current pulse based (1500KB) | 期刊论文 | 出版稿 | 开放获取 | CC BY-NC-SA | 浏览 下载 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论