Institutional Repository of Key Laboratory of Coastal Zone Environmental Processes, Yantai Institute of Coastal Zone Research, Chinese Academy of Sciences (KLCEP)
Polymeric membrane potentiometric sensors based on template-removal-free imprinted receptors for determination of antibiotics | |
Wang, Xinyao1,2; Cui, Guohua1; Liang, Rongning1; Qin, Wei1 | |
发表期刊 | ANALYTICAL METHODS |
ISSN | 1759-9660 |
2024-05-23 | |
卷号 | 16期号:20页码:3240-3248 |
DOI | 10.1039/d4ay00263f |
通讯作者 | Liang, Rongning([email protected]) |
英文摘要 | Currently, Nernstian-response-based polymeric membrane potentiometric sensors using molecularly imprinted polymers (MIPs) as receptors have been successfully developed for determination of organic ionic species. However, the preparation of these MIP receptors usually involves tedious and time-consuming template-removal procedures. Herein, a template-removal-free MIP is proposed and used as a receptor for fabrication of a potentiometric sensor. The proposed methodology not only significantly shortens the preparation time of MIP-based potentiometric sensors but also improves the batch-to-batch reproducibility of these sensors. By using antibiotic vancomycin as a model, the new concept offers a linear concentration range of 1.0 x 10-7 to 1.0 x 10-4 mol L-1 with a detection limit of 2.51 x 10-8 mol L-1. It can be expected that the template-removal-free MIP-based sensing strategy could lay the foundation for simple fabrication of electrochemical sensors without the need for template removal such as potentiometric and capacitive sensors and ion-sensitive field-effect transistors. A template-removal-free strategy for simple and robust fabrication of MIP-based potentiometric sensors is demonstrated for the first time. |
资助机构 | National Natural Science Foundation of China ; National Natural Science Foundation of China ; Key Deployment Project of Centre for Ocean Mega-Research of Science, Chinese Academy of Sciences ; Taishan Scholar Program of Shandong Province |
收录类别 | SCI |
语种 | 英语 |
关键词[WOS] | ION-SELECTIVE ELECTRODES ; LOWER DETECTION LIMIT ; SENSITIVE DETECTION ; COEFFICIENTS |
研究领域[WOS] | Chemistry ; Food Science & Technology ; Spectroscopy |
WOS记录号 | WOS:001217154800001 |
引用统计 | |
文献类型 | 期刊论文 |
条目标识符 | http://ir.yic.ac.cn/handle/133337/36084 |
专题 | 中国科学院海岸带环境过程与生态修复重点实验室 中国科学院海岸带环境过程与生态修复重点实验室_海岸带环境过程实验室 |
通讯作者 | Liang, Rongning |
作者单位 | 1.Chinese Acad Sci, CAS Key Lab Coastal Environm Proc & Ecol Remediat, Shandong Key Lab Coastal Environm Proc, Yantai Inst Coastal Zone Res YIC,YICCAS, Yantai 264003, Shandong, Peoples R China 2.Univ Chinese Acad Sci, Beijing 100049, Peoples R China |
推荐引用方式 GB/T 7714 | Wang, Xinyao,Cui, Guohua,Liang, Rongning,et al. Polymeric membrane potentiometric sensors based on template-removal-free imprinted receptors for determination of antibiotics[J]. ANALYTICAL METHODS,2024,16(20):3240-3248. |
APA | Wang, Xinyao,Cui, Guohua,Liang, Rongning,&Qin, Wei.(2024).Polymeric membrane potentiometric sensors based on template-removal-free imprinted receptors for determination of antibiotics.ANALYTICAL METHODS,16(20),3240-3248. |
MLA | Wang, Xinyao,et al."Polymeric membrane potentiometric sensors based on template-removal-free imprinted receptors for determination of antibiotics".ANALYTICAL METHODS 16.20(2024):3240-3248. |
条目包含的文件 | 条目无相关文件。 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论