Translating potentiometric detection into non-enzymatic amperometric measurement of H2O2
Yin, Tanji1,2,4,5; Wang, Hemin1,2,3; Li, Jinghui1,2,4,5; Yuan, Baiqing3; Qin, Wei1,2,4,5
发表期刊TALANTA
ISSN0039-9140
2021-09-01
卷号232页码:7
关键词Ion-selective electrodes Amperometric readout H2O2 Ca2+ NO3-
DOI10.1016/j.talanta.2021.122489
通讯作者Yin, Tanji([email protected]) ; Yuan, Baiqing([email protected])
英文摘要The developments of alternative signal readout strategies for the ion-selective electrodes (ISEs) are necessary in order to break through the limitation of the Nernst equation. In this work, a simple, convenient and easily operated strategy based on the non-enzymatic amperometric measurement of H2O2 is proposed to read out the potentiometric responses for the ISEs. The proposed amperometric signal readout based on H2O2 is carried out in a two compartment electrochemical cell configuration containing a detection cell and a sample cell, physically connected by a salt bridge. A glassy carbon (GC) electrode is placed in the detection cell to monitor the oxidation current of H2O2, and an ISE is placed in the sample cell to act as both the reference electrode and the potentiometric sensor for obtaining the ion activities. The oxidation of H2O2 is induced by a constant potential applied between the GC electrode and the ISE, and subsequently modulated by the potential change of the ISE in the presence of the primary ion. The proposed amperometric signal readout based on H2O2 shows the satisfied slope sensitivity and detection limit, which are better than or compared to those for the potentiometric responses for the ISEs. This work provides a general strategy for transforming the potential response of the ISEs into the amperometric readout, and is promising for detection of cations (eg., Ca2+) and anions (eg., NO3-) with high sensitivity and excellent selectivity.
资助机构National Natural Science Foundation of China ; Key Project of the Natural Science Foundation of Shandong Province ; Key Deployment Project of Centre for Ocean Mega-Research of Science, Chinese Academy of Sciences ; Taishan Scholar Program of Shandong Province ; National Key Research and Development Program of China
收录类别SCI
语种英语
关键词[WOS]SELECTIVE ELECTRODES ; ION ; MEMBRANE ; READOUT ; HEPARIN
研究领域[WOS]Chemistry
WOS记录号WOS:000658317000068
引用统计
被引频次:12[WOS]   [WOS记录]     [WOS相关记录]
文献类型期刊论文
条目标识符http://ir.yic.ac.cn/handle/133337/29422
专题中国科学院海岸带环境过程与生态修复重点实验室
中国科学院海岸带环境过程与生态修复重点实验室_海岸带环境过程实验室
通讯作者Yin, Tanji; Yuan, Baiqing
作者单位1.Chinese Acad Sci, Yantai Inst Coastal Zone Res YIC, Key Lab Coastal Environm Proc & Ecol Remediat, Yantai 264003, Shandong, Peoples R China
2.YICCAS, Shandong Prov Key Lab Coastal Environm Proc, Yantai 264003, Shandong, Peoples R China
3.Ludong Univ, Sch Chem & Mat Sci, Yantai 264025, Shandong, Peoples R China
4.Pilot Natl Lab Marine Sci & Technol, Lab Marine Biol & Biotechnol, Qingdao 26620, Peoples R China
5.Chinese Acad Sci, Ctr Ocean Megasci, Qingdao 266071, Shandong, Peoples R China
推荐引用方式
GB/T 7714
Yin, Tanji,Wang, Hemin,Li, Jinghui,et al. Translating potentiometric detection into non-enzymatic amperometric measurement of H2O2[J]. TALANTA,2021,232:7.
APA Yin, Tanji,Wang, Hemin,Li, Jinghui,Yuan, Baiqing,&Qin, Wei.(2021).Translating potentiometric detection into non-enzymatic amperometric measurement of H2O2.TALANTA,232,7.
MLA Yin, Tanji,et al."Translating potentiometric detection into non-enzymatic amperometric measurement of H2O2".TALANTA 232(2021):7.
条目包含的文件 下载所有文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
Translating potentio(3212KB)期刊论文出版稿开放获取CC BY-NC-SA浏览 下载
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Yin, Tanji]的文章
[Wang, Hemin]的文章
[Li, Jinghui]的文章
百度学术
百度学术中相似的文章
[Yin, Tanji]的文章
[Wang, Hemin]的文章
[Li, Jinghui]的文章
必应学术
必应学术中相似的文章
[Yin, Tanji]的文章
[Wang, Hemin]的文章
[Li, Jinghui]的文章
相关权益政策
暂无数据
收藏/分享
文件名: Translating potentiometric detection into non-enzymatic amperometric measurement of H2O2.pdf
格式: Adobe PDF
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。